Welcome to Kena Environmental Technology Co., LTD
1/2
1/2

The maintenance skills of electric heating fan water tk

Views : 768
Update time : 2024-06-30

Maintenance techniques for electric heating
After using it for a period of time, there is a layer of foreign body and dust on the surface of the electric heating.If it is not cleaned, it will affect heat dissipation.After running for a long time, the fan should be maintained and replaced.The operation process must be judged and maintained by full -time personnel, and the motor shall not be demolished without permission.This will easily cause short circuits, and the motor will not rotate.If it is light, it will burn insurance, and severe causing the cable burns to the fire.
The ventilation pipe of the electric heating fan cannot be removed, which can easily cause the motor to be excessive and burnt. The gear transmission resistance can be replaced by the gear. If the first and second gear are used for a long time, the resistance is easy to burn or affect the normal use.If you find this problem, replace it in time.After the operating system is used for a long time, the operation cable is prone to aging and deforming, making the operation not flexible or not in place.Do not move hard to avoid damaging parts.
If you find this problem, you should judge at the maintenance station and repairs and replace them according to the specific situation.Ventilation pipelines, No. 1 and No. 2 rubber hose of electric heaters, are used at high temperatures for a long time, which is easy to aging and cracking.If the problem is found, it should be replaced in time to avoid leakage, resulting in high water temperature, and the engine gas cylinder head deforms.The replacement of the hose should be provided by Li Xia Motor Company, and the inferior hose is not resistant to corrosion.
Pay attention to the following points to use this device: When the winter temperature is below 0, there will be a layer of ice and frost on the front windshield to start the engine. When the water temperature rises above 40, place the operation at the frost position according to the logo, place it in the frost position, and place it in the frost position.The indoor circulation location, open the drum wind motor, put it in the three gear. At this time, the speed of the electric heater is high, so it can run for 3-5 minutes, and then place the gear in the first and second positions according to the frost situation.Essence
During this period, if the motor was not turned, he should immediately return the motor gear to the closed position to avoid burning the transmission resistor.When the outdoor temperature is low and there are many drivers and passengers in the cab, the glass will be frosting, and the operation can be placed in the defrost position and outdoor circulation position. The motor can be placed in the first or second gear.
When there is no sand and dust outside, you can circulate outdoors.If there are sand and dust or the weather, the circular device is placed in the room to avoid sand and dust from entering the cab.After reading the above content, if you have other questions about electric heaters products, please contact us. We look forward to reaching cooperation with you.
Border wall explosion -proof shaft flow fan rainfall and insect -proof edge wall fan
Tall space ceiling air -conditioner small vibration and small use safety reliability high
Tall space ceiling air -conditioning unit work efficiency high maintenance costs are low
Tall space air -conditioning units of air circulating heat -making unit running stable wireless control
Tall space warm and warm units Low warm wind crew warehouse plant heating and refrigeration equipment
Tall space dedicated circular air and hot and cold units operate steadily, energy saving low -carbon quality high
Wall -style exhaust lane aluminum -style wall fan square wall stroke fan
The side wall of the side wall is strong, thick, material integrated molding

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s

Leave Your Message


TOP