The combined air -conditioning unit is a kind of air treatment equipment assembled from various air treatment functions.Suitable for air -conditioning systems with resistance greater than 100Pa.The air treatment function section of the crew is: air mixed, balanced, filtering, cooling, primary and secondary heating, dampness, humidification, delivery, water spraying, sounding sound, heat recovery, and other units.
The air volume of combined clean air -conditioning units from 3500m3/h to 200000m3/h is a total of 12 types of functional segments for users to choose the combination freely.It is mainly suitable for the air purification system of various cleaning plants.Such as industrial electronics factories, machinery manufacturers, textile workshops, automobile spray workshops, GMP pharmaceutical factories, cosmetics, food factories, pure water workshops, hospital surgery, ICU and other occasions.
Classified by structure type can be divided into horizontal, vertical and ceiling type; classification according to the characteristics of the purpose, it can be divided into general universal crews, fresh air units, purification units, and special crews (such as roof units, subway units, and computer room -specific units, etc.Wait); can also be classified according to specifications, and the basic specifications of the unit can be represented by the rated air volume.
The setting of the functional section of the purification unit shall be determined according to the requirements of the production process or clean room, which is the basic principle.The merger and choice of the functional section of the purification unit should be closely combined with the design of the air -conditioned room.
Microbial pollution points in the purification unit must be controlled.Because the structure, temperature and humidity are more suitable for the growth of microorganisms such as bacteria, the boxes, filters, mufflers, humidifiers, etc. of the units have become potential microbial pollution points, and they must be controlled.For example, the unit box should be free of damage, rusty, disinfected, thermal insulation and sealing performance. It can be used as a antibacterial material that has been widely used in the refrigerator; the filter performance indicators meet the requirements;; Often clean or disinfection in the unit.
The above is the analysis of the selection of combined air conditioning. I hope that the above content can be helpful to everyone. Thank you for your viewing and support. In the later period

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s

Leave Your Message