Introduction to a combined air -conditiing unit

Views :
Update time : 2024-06-30

The air volume of combined clean air -conditioning units from 3500m3/h to 200000m3/h is a total of 12 types of functional segments for users to choose the combination freely.It is mainly suitable for air purification systems of various clean factories, such as industrial electronics plants, precision machinery manufacturers, textile workshops, automobile spray workshops, GMP pharmaceutical plants, cosmetics, food factories, pure water workshops, hospital surgery, ICU and other typesoccasion.
Classified by structure type can be divided into horizontal, vertical and ceiling type; classification according to the characteristics of the purpose, it can be divided into general universal crews, fresh air units, purification units, and special crews (such as roof units, subway units, and computer room -specific units, etc.Wait); can also be classified according to specifications, and the basic specifications of the unit can be represented by the rated air volume.
The setting of the functional section of the purification unit shall be determined according to the requirements of the production process or clean room, which is the basic principle.The merger and choice of the functional section of the purification unit should be closely combined with the design of the air -conditioned room.
Microbial pollution points in the purification unit must be controlled. Due to the growth of microorganisms such as the structure, temperature and humidity, the box, filter, muffler, humidifier, etc. of the crew of the unit becomes potential microbial pollution points.Control.For example, the unit box should be free of damage, rust, disinfection, thermal insulation and sealing performance. It can be used as a antibacterial material that has been widely used on the refrigerator; the filter performance indicators meet the requirements, and the muffler, humidifier and other non -retention can be reserved., Often clean or disinfection in the unit.
New Backwind Mixed Section
1. The position of the new return air outlet can be set on the end, top, or left and right sides according to the design requirements.On the new return air outlet, the installation valve can be installed. The execution agency has three types: manual, electric and pneumatic, which is selected by users.
2. There are two types of filtering sections: early and medium -efficiency filtration, with diamond -shaped bag type, four -peak bag type, and can also be equipped with automatic rolling type. The filter material has no woven fabric with high -quality polyester wheels.Institution, cover and alarm device.
New rowing section
(Also known as Pingding Division Wind Mixed Section) There is a wind return valve in the box in this section. There is a row of air outlets and new air outlets on each top of the boxes before and after the valve.The air -conditioning machine discharge part of the wind, so that the fresh air and a return air are mixed according to the required proportion; when the DC system is used in the transition season, the air return valve should be turned off to open the exhaust valve and the new wind valve.
Energy recovery section
For double wind turbine systems for cross -separation and exhaust energy recycling.There is a wind return valve in the box in this section, and the top is an energy recyler. It is an indirect cooling (heating) fresh air that uses the cold (heat) of the exhaust.About 60%of energy.At the same time, the exhaust and fresh air do not directly contact, and it is particularly suitable for the energy recovery of the DC air conditioning system of the harmful gas indoor.When using the DC system, it should be closed once the air return valve should be closed. There should be a separate air exhaust system in the venue venue, and this section should not be used.
Middle section (maintenance section)
The connection and internal maintenance and lighting of the crew from the transition section.Before the filtering section, the intermediate section must be set up before and after the surface of the surface, heating section, and the disappearance section.
Secondary background
Connect the middle section of the second air supply pipe, and the top can be provided with a regulatory valve, equipped with a manual, electric or pneumatic regulatory mechanism, which is selected by the user.
The cooler adopts the structure of aluminum foil with a copper tube of 4, six, and eight tubes. The aluminum foil is the form of double -edged ripple edges.The form of mechanical rising tube guarantees the contact performance of the heat exchanger. The thermal exchanger is divided into two types: fixed and rotating type. Users can choose one as needed. The heat media uses steam or hot water.
The above is an introduction to the combined air -conditioning unit. If you want to know more information, please pay more attention to us- ——

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s